Compact multi-parameter water quality analyzer for secondary water supply and distribution — simultaneous free chlorine / ClO₂, turbidity, pH, conductivity and temperature in one wall-mounted unit.
- Five key drinking water safety parameters in one compact unit
- Reagent-free electrode measurement — very low operating cost
- Purpose-built for unattended pump rooms and rural stations
- Remote data upload for centralized supervision of dispersed sites
Overview
A multi-parameter water quality analyzer combines several sensors in a single monitoring unit. At secondary supply and distribution points it continuously tracks the parameters that define drinking water safety — disinfectant residual, turbidity, pH, conductivity and temperature.
The TMS-E3000 is a multi-parameter water quality analyzer developed for monitoring rural drinking water and secondary water supply, designed in compliance with CJJ/T 271-2017 — the technical standard for online monitoring of urban water supply quality. It integrates electrode-based free chlorine / chlorine dioxide measurement with low-range turbidity, pH, conductivity and temperature sensing in a flow-through assembly, engineered for high reliability, long maintenance intervals and unattended operation in remote or decentralized locations.
Typical Applications
Features
- Low operating cost — only one consumable (pH electrode); self-cleaning turbidity and chlorine sensors reduce maintenance frequency and cost
- High accuracy — turbidity sensor designed for drinking water, capable of measuring below 0.1 NTU; chlorine measurement with flow stabilization and automatic pH / temperature compensation for disinfectant dosing guidance
- High reliability — optimized for high-turbidity rural drinking water systems; high-purity platinum chlorine electrode with no membrane or electrolyte tolerates no-chlorine, intermittent-flow and low-pressure conditions
- Compact integrated design — all parameters housed in one 30 × 40 × 18 cm enclosure, ideal for retrofits in small pump rooms or limited-space rural water stations
Specifications
| Parameter | Specification |
|---|---|
| Measured Parameters | Turbidity, free chlorine / chlorine dioxide, pH, conductivity (optional), temperature |
| Turbidity | 90° scattering; 0–20 NTU (optional 0–100 NTU); resolution 0.001 NTU; ±2% or ±0.02 NTU (whichever is greater); response ≤ 0.5 min |
| Free Chlorine / ClO₂ | Three-electrode amperometric method; 0–2 mg/L (optional 0–5 mg/L); resolution 0.001 mg/L; ±5% or ±0.03 mg/L (0–2 mg/L), ±10% (2–5 mg/L); response ≤ 2 min |
| pH | Electrochemical; 0–14 pH; resolution 0.01 pH; accuracy ±0.1 pH; response ≤ 0.5 min |
| Conductivity (optional) | Four-electrode method; 0–10 mS/cm (optional 0–100 mS/cm); resolution 0.01 µS/cm; ±1.5% F.S. or ±0.05 µS/cm; response ≤ 0.5 min |
| Temperature | NTC10K thermistor; -5 to 60 °C; resolution 0.01 °C; accuracy ±0.2 °C |
| Display | PC panel with 7-inch color touchscreen |
| Power Supply | 85–264 VAC, 50/60 Hz; average 15 W, max. 35 W |
| Communication | 1 × RS485 interface (Modbus RTU protocol); wireless data upload |
| Dimensions | 30 × 40 × 18 cm (W × H × D) |
| Weight | 10 kg |
| Installation | Wall-mounted / panel-mounted, flow-through sampling |
| Operating Temperature | Controller: -10 to 50 °C; Sensor: -15 to 55 °C |
| Sample Temperature | 5–40 °C |
| Sample Flow Rate | Turbidity: 320–1000 mL/min; other parameters: > 180 mL/min |
| Sample Pressure | 1–4 bar |
| Relative Humidity | < 90%, non-condensing |
Frequently Asked Questions
Related Products

Dual-angle infrared scattering analyzer for continuous turbidity and suspended solids measurement in wastewater and drinking water processes.

High-precision low-range turbidity analyzer for drinking water treatment and filtration monitoring.

Integrated digital turbidity sensor using infrared scattering — self-cleaning option and digital Modbus networking for unattended monitoring points.
Need a customized water monitoring solution?
Contact our engineers today — share your application and we will configure the right instruments for your project.